logo

1 303 279 1021

Loading

Live Chat

img
Strater Version Info

Strater 2

Strater 2.5.704 (September 22, 2011)

  • Sheets for some XLSX files were displayed in the wrong order in the XLSX Import Options dialog box
  • Reloading data reloaded the wrong table from an Access MDB or ACCDB file
  • The Object Positioning was not remembered for scale bar objects
  • Some logs were displayed at incorrect depths
  • Reinstallation overwrote the user-writeable directory with original versions of the files

 

Strater 2.4.615 (June 30, 2011)

  • Could not select -Empty- as Hole ID from ID Filter drop down menu
  • Logs did not update immediately after adding data to the data table, if the data was added using the arrow keys to move between cells
  • Strater would crash when importing some LAS files into existing data tables
  • Depth grid lines were displayed incorrectly when variable grid lines were out of the data range
  • Some logs were displayed at incorrect depths after changing page sizes, pane sizes or pane visibility
  • Strater would crash when viewing fill patterns for numerous items in the Scheme Editor
  • Strater would crash when importing some TIF files
  • Scale bars set to User Defined were still deleted when logs they used to be attached to were deleted
  • When importing some XLSX files, Strater misidentified sheet names as sheet1, sheet2, sheet3, etc.

 

Strater 2.3.517 (April 1, 2011)

  • Linked text sometimes did not recognize new data in the linked tables when the tables were created from a template
  • Import LAS did not recognize well data tables that were created from templates or in another instance of Strater
  • Line logs were discontinuous when the data went outside the data extents for the log
  • Grid lines were not shown correctly when the log had no data
  • Grid lines separated from the line plot they were drawn for when there was no data
  • Changing the Update Interval under Tools | Options generated "Value must be >=1 and <=100" error
  • Line logs created from an interval table could not be discontinuous
  • The background properties for font were not applied to complex text logs
  • Strater would sometimes crash when double clicking an SDG file, or generate an error when using File | Open (BHBase.cpp, Line 1119)
  • Single points are not visible in a line/symbol log with a user defined data range
  • Strater would either crash or not import some Lotus Worksheet WK? files properly
  • Strater would sometimes crash when canceling an import or export procedure

 

Strater 2.2.351 (October 25, 2010)

  • Strater would sometimes crash when a user double clicked on an SDG file.
  • Strater would sometimes generate an error when using File | Open to open an SDG file (BHLineSymbol.cpp or StraterView.cpp).
  • Internal error and crash was generated when changing a column name that was referenced by a percentage log.

 

Strater 2.1.315 (September 21, 2010)

  • Cutoff values for line logs below 1 were displayed as 0 in the Property Manager
  • The Custom page Height was limited to 33"
  • Current Page linked text item always showed "1" when printed
  • The top separator line in a complex text log did not show ticks
  • Text in complex text logs would change position depending on if the separator line was shown or not
  • Text in complex text logs would sometimes overlap
  • Some text blocks in a complex text log did not change vertical alignment
  • There were some redraw issues when drawing a polygon or polyline and scrolling or zooming at the same time
  • Internal Errors were generated when loading a data file that had trailing spaces in the column names
  • Internal Errors were sometimes generated when changing the data table for a log
  • Strater didn't export multi-page documents to EMF files correctly
  • New feature added: the depth value of the cursor location is displayed in the status bar

 

Strater 2.0.276 (August 14, 2010)

  • Strater 2 released

Strater 1

Strater 1.4.33 (August 2, 2005)

  • Updated the code to properly size graphic items in a graphic log.
  • The Hole ID no longer is reset to a new default when a log item was created.
  • Fixed a problem where you could not change the symbol size under File | Preferences | Default Symbol using the up arrow to anything greater than 0.04 inches.
  • Importing data into a Collars table automatically sets the combo boxes in the "Specify Column Definitions" section if the names are the same.
  • Fixed a problem where changing the display units from inches to centimeters wouldn't properly regenerate the log depth settings if set to automatic.
  • Fixed a problem where some linked text fields would display a temporary string "Strater87654" when no real data existed for the field.
  • Strater is no longer left in a locked state when attempting to open newer file formats.
  • The property inspector now displays the correct Data Field when similar names are present in the table.
  • Automatic scaling now correctly calculates the scaling depth when the project is set to centimeters for page units.
  • Fixed a problem where importing some numeric data into a Collars could result in the display of a number with a bunch of trailing 0's.
  • When a Lithology Indent Styles scheme is saved and then loaded into a new project, the scheme now saves the actual Line Indent Style.
  • Fixed a problem where loading a template file, importing data, and then switching the view mode from Design Mode to Active Mode could lead to a crash.
  • When creating a custom vector pattern by editing the Sand pattern, the new custom pattern will show up in the preview window.
  • Strater no longer locks up and crashes if you change the Grid Division option to 0 under File | Preferences with the grid displayed.
  • If you set the angle of the depth log labels to anything between than 90° and 271°, the text no longer gets inverted like if you’re looking at the reverse of the text.
  • Fixed a problem where the Range schemes did not save the text properties when you either closed and reopened an SDG file or if you saved and loaded a SCH file.
  • Fixed a problem where changing the linked text font properties could result in Strater improperly redrawing the window.
  • Exporting data from a Project Settings table no longer results in a Strater error.
  • Improved a problem when you use an interval table to create a lithologic log, and save it to a template, the interval table in the template looses some of the fields.
  • Improved a problem where if you have an interval table, and have logs that can use an interval or depth table in the borehole view, and save the SDG file to a template, the template stores the interval table as a depth table.
  • Modified the Database View export code to double up any text qualifier characters appearing inside the ASCII representation of the field’s contents.
  • When you go to import a bitmap into the Picture Pattern dialog, the options under "Files of type" now show all the bitmap formats (i.e. BMP, GIF, JPG, TIF, PNG, etc.).
  • Modified the sample file Mudlog Example-1.sdg.
  • Modified the sample file Lith Section-1.sdg.
  • Updated the LAS import filter to support tab delimited data.

 

Strater 1.03.30 (January 26, 2005)

  • Database code will correctly read and import SQL Numeric field types.
  • File | Preferences no longer makes the Close Window "X" in the upper right disappear.
  • Removed the Show Position check box option located under Vertical and Horizontal Ruler Preference Properties.
  • If nothing is selected, the Edit | Cut command and the Cut icon on the toolbar are no longer active.
  • When you reload certain XLS files, some numbers are no longer updated with a bunch of trailing 0's.
  • When importing certain database files, some numbers are no longer imported with many trailing 9's.
  • Changing the Header Pane height in the Page Setup dialog box no longer results in Strater creating an extra page.
  • When a linked text object is created with no borehole names defined, a blank text object was created. The object will now display the text "-Empty-". This will match the text contained in the Borehole View Properties section.
  • When a linked text object contains no text, the object no longer disappears from the borehole view.
  • Strater now allows you to drag a log width to be less than 0.6 cm (or 0.25 in) and use the Base Properties | Positioning | Width option in the Property Inspector without error.
  • Wrapping works properly when user defined starting and ending scaling values are defined.
  • Depth logs properly nudge the starting or ending labels.
  • Modifying the properties of a depth log no longer impacts the complete redrawing of some borehole items.
  • Linked text objects no longer throw an internal error when the field items were invalid or no long present.
  • Added code to prevent saving templates in the demo version.
  • The Reload Data command updates the data if the table name contains any spaces.
  • Added a special setting to the INI file to set the scaling value for automatic and collars log calculations.
  • Modified the feedback e-mail text messages.

 

Strater 1.02.27 (September 17, 2004)

  • Resetting the Header and Footer pane sizes of some project files no longer results in a crash.
  • Trailing 0’s are no longer imported after some numbers from some data files.
  • A second, empty page is not created when using a Collars Table for the Depth Settings.
  • Text tables are now created in the database view when a template is loaded into a project.
  • The display units on depth logs always agree with the depth units for the borehole view.
  • The line style sample shown in the property inspector now updates when the user changes the line end styles.
  • The Back button is no longer active in the first dialog box when importing an MDB file.
  • Fixed a problem when you reload the data and click Cancel, or if you click "Update Borehole Data", you get an internal error.
  • The object manager now completely refreshes when a template is loaded into a project.
  • The entire log is now displayed when the Wrap Style is set to wrap for logs that have the variable max value specified to a smaller value than the data.
  • Areas with no data for line/symbol logs are no longer filled when a fill is specified.
  • All the well item styles for the well construction log will fill the entire interval.
  • NULL data values will no longer be used for post and class post logs.
  • NULL values will no longer be used in the calculation of range schemes.
  • If a user has empty or text values in the data field of a classed post log, Strater no longer gives these values a huge number to make the default classes get out of range.
  • The sort option is now disabled for collars and text type tables.
  • Strater no longer crashes with a gsimage2.dll error if a user selects text over and over again in the Text Editor.
  • When you set the depth log to show elevation, the ending tick labels are now nudged when Nudge End Values is set to True.
  • Scheme files that contained lithologic indent line styles no longer leads to a crash.
  • The Linked Text object type always shows the correct page number when printing or exporting the pages.
  • The complex text log now shows the text in projects with positive to negative depths.
  • Importing a picture pattern and resetting the DPI no longer results in Strater locking up and displaying the error "Bad Parameter Passed".

 

Strater 1.01.26 (May 15, 2004)

  • If you export a GSI file containing text and import it into the header pane, the text is no longer inverted.
  • Log items that use range schemes now correctly use the last range interval when displaying the log item.
  • The major tick marks can now be changed to a value smaller than the minor tick marks.
  • When you have your page units set to CM and you try to change the Minor Tick Length to something smaller, the Minor Tick Length no longer settles at 1.61 cm.
  • The scale on the scale bar now updates immediately when changes are made to the variable grid line properties section.
  • Made an adjustment to the way the Scaling Depth per Inch is calculated when the depth settings is set to Collars.
  • Made a minor adjustment to the way the scaling values are automatically calculated for depth logs.
  • The Load button no longer becomes active early in the data import process.
  • When there is an empty borehole id and the view is set to Page View, you can now access the other pages.
  • Post and Classed Post logs no longer ignore the text properties specified in the respective schemes.
  • The text alignment property now is applied correctly for all log types.
  • If you have 7 or more decimal digits in your data, when you import the file – Strater no longer rounds up to 6 decimal digits and formats the number in exponential format.
  • Strater updates the depth scale settings when a new single well entry is added to the database view.
  • With a log/log crossplot log, the depth grid lines will now go all the way across the log. In addition, the scale bar ticks and tick mark labels will be correct.
  • Corrected a problem where the Line/symbol logs with no data applied would appear to not move when the user moves the log item.
  • Disabled the ability to save files in the demo when the user closes the program.
  • Corrected a problem where Strater would create a default fill for lithologic logs that contained an empty lithologic keyword item.
  • Corrected the problem where the depth grid line properties had an incorrect label for "Grid Maximum". It was also set to "Grid Minimum".
  • The Export Data command now properly specifies the default export path.
  • Corrected a problem where if you an SDG file with text tables in it and save it to a template, then load the template into a new project, the text table is missing.
  • Corrected a problem where if you set a custom borehole starting depth and have a complex text log, the text entries still start from the beginning of the data file and are all overwritten at the top of the log.

 

Version 1.00 (March 1, 2004)

  • Strater was released

 

Trusted by over 10,000 Companies and Schools